RDP303-7.6K Mode 2 EV Charging Main Control Board


  • Model

    RDP303-7.6K

    Parameters

    Operating voltage: 120/240Vac

    Output power: 7.6kW Max.

    Output current: 32A Max.

    Features

    — Adjustable/customizable output current

    — All-around protection: OTP/OCP/OVP/UVP/surge protection

    — Wi-Fi/Bluetooth interfaces reserved

    — Input plug over-temperature protection interface reserved

    — High-performance MCU & optimized operating logic

    — RCD CCID20

    — Meets US standard

    Certifications

    UL

    Applications

    GB mode 2 EV chargers, IEC mode 2 EV chargers

    Subject to change without notice. Errors and omissions excepted. Always make sure to use the most recent release.

Show more

Keywords:

Category:

Products

Products

EV charger control board

RDP303-7.6K Mode 2 EV Charging Main Control Board
  • RDP303-7.6K Mode 2 EV Charging Main Control Board
  • 产品描述
  • Parameter
  • Data Sheet
  • Model

    RDP303-7.6K

    Parameters

    Operating voltage: 120/240Vac

    Output power: 7.6kW Max.

    Output current: 32A Max.

    Features

    — Adjustable/customizable output current

    — All-around protection: OTP/OCP/OVP/UVP/surge protection

    — Wi-Fi/Bluetooth interfaces reserved

    — Input plug over-temperature protection interface reserved

    — High-performance MCU & optimized operating logic

    — RCD CCID20

    — Meets US standard

    Certifications

    UL

    Applications

    GB mode 2 EV chargers, IEC mode 2 EV chargers

    Subject to change without notice. Errors and omissions excepted. Always make sure to use the most recent release.

  • Electrical data

    Input voltage

    Rated 120/240Vac

     

    Input frequency

    60Hz

     

    Output voltage

    Rated 120/240Vac

     

    Output current

    32A max.

    6A-32A adjustable

    Output power

    7.6kW max.

    Adjust the power according to the current

    Stand-by power 

    consumption

    <5W

    Power in non-charging state

    Man-machine interaction

    Communication mode

    Serial digital interface

    Mainly used for external WIFI/Bluetooth modules

    Man-machine interaction

    Screen/indicator light/key interface

    Used with RDC201-02

    Charger-enable

    Plug & charge

    The charging logic can be adjusted via software

    Operating conditions

    Ambient temperature 

    range

    -30℃~+50℃

    Ultimate temperature for the test of the matching housing (relay Tc<110℃)

    Temperature range at 

    storage

    -40℃~+85℃

     

    Humidity during operation

    5%-95%, no condensation

     

    Operating altitude

    < 3000m

     

    Dimensions

    Size

    160*74*29.5mm

     

    Installation method

    Mode 2

     

    Product weight

    180g

     

    Protection

    Leakage 

    CCID20

     

    Surge 

    L-N: ±2000V   L/N-PE: ±4000V

     

    Ground 

    With ground protection function

    The screen displays the corresponding fault, and the emergency charging state is entered through manual control. Re-powering on can restore the error report

    Overcurrent 

    >current value set +2A

     

    Overvoltage 

    Input voltage≥270Vac

     

    If 270Vac is maintained for 2 seconds, an alarm will be triggered and the relay will be disconnected immediately. Normal operation is restored until the voltage is identified to be less than 260Vac for 2 consecutive seconds

    Undervoltage 

    Input voltage≤170Vac

    If 170Vac is maintained for 2 seconds, an alarm will be triggered and the relay will be disconnected immediately. Normal operation is restored until the voltage is identified to be greater than 180Vac for 2 consecutive seconds

    Plug over-temperature 

    NTC temp. >70℃

    Turn off the output

    Relay welding 

    Relay welding

    The screen displays the corresponding fault

    Emergency plug 

    disconnection

     

    Return to standby mode after emergency disconnection

    Safety & certification

    Insulating strength

    Input L&N-PE

    Output L&N-PE

    Input L&N-CP

     

     

    AC:2U+1200V

    60S, <20mA

    During testing, the test sample must not exhibit insulation breakdown or arcing phenomena at any test point

    Insulation resistance

    Input L&N-PE

    Output L&N-PE

    Input L&N-CP

     

     

    DC: 500V,

    60S, >5MΩ

    Test after short-circuiting the input L and N, as well as the output L and N respectively