RDP109-7K2 Mode 2 EV Charging Main Control Board
-
Model
RDP109-7K2
Parameters
Operating voltage: 220-240Vac
Output power: 7.2kW Max.
Output current: 32A Max.
Features
— Adjustable/customizable output current
— All-around protection: OTP/OCP/OVP/UVP/surge protection
— Wi-Fi/Bluetooth interfaces reserved
— Input plug over-temperature protection interface reserved
— High-performance MCU & optimized operating logic
— RCD Type A+DC6mA
— Meets EU & China GB standards
— TUV certified
Certifications
CE
Applications
GB mode 2 EV chargers, IEC mode 2 EV chargers
Subject to change without notice. Errors and omissions excepted. Always make sure to use the most recent release.
Keywords:
Category:
Products
Products
EV charger control board
- 产品描述
- Parameter
- Data Sheet
-
Model
RDP109-7K2
Parameters
Operating voltage: 220-240Vac
Output power: 7.2kW Max.
Output current: 32A Max.
Features
— Adjustable/customizable output current
— All-around protection: OTP/OCP/OVP/UVP/surge protection
— Wi-Fi/Bluetooth interfaces reserved
— Input plug over-temperature protection interface reserved
— High-performance MCU & optimized operating logic
— RCD Type A+DC6mA
— Meets EU & China GB standards
— TUV certified
Certifications
CE
Applications
GB mode 2 EV chargers, IEC mode 2 EV chargers
Subject to change without notice. Errors and omissions excepted. Always make sure to use the most recent release.
-
Electrical data
Input voltage
Rated 220-240Vac
Limit 170-270V; Protection is implemented beyond this range
Input frequency
50/60Hz
Output voltage
Rated 220-240Vac
Limit 170-270V; Protection is implemented beyond this range
Output current
32A max.
6A-32A adjustable
Output power
7.2kW max.
Adjust the power according to the current
Stand-by power
consumption
<5W
Power in non-charging state
Man-machine interaction
Communication mode
Serial digital interface
Mainly used for external WIFI/Bluetooth modules
Man-machine interaction
Screen/indicator light/key interface
Used with RDC201-02
Charger-enable
Plug & charge
The charging logic can be adjusted via software
Operating conditions
Ambient temperature
range
-30℃~+50℃
Ultimate temperature for the test of the matching housing (relay Tc<110℃)
Temperature range at
storage
-40℃~+85℃
Humidity during operation
5%-95%, no condensation
Operating altitude
< 3000m
Dimensions
Size
150*65*29.5mm
Installation method
Mode 2
Product weight
150g
Protection
Leakage
Type A+DC6mA
Surge
L-N: ±2000V L/N-PE: ±4000V
Ground
With ground protection function
The screen displays the corresponding fault, and the emergency charging state is entered through manual control. Re-powering on can restore the error report
Overcurrent
>current value set +2A
Overvoltage
Input voltage≥270Vac
If 270Vac is maintained for 2 seconds, an alarm will be triggered and the relay will be disconnected immediately. Normal operation is restored until the voltage is identified to be less than 260Vac for 2 consecutive seconds
Undervoltage
Input voltage≤170Vac
If 170Vac is maintained for 2 seconds, an alarm will be triggered and the relay will be disconnected immediately. Normal operation is restored until the voltage is identified to be greater than 180Vac for 2 consecutive seconds
Plug over-temperature
NTC temp. >70℃
Turn off the output
Relay welding
Relay welding
The screen displays the corresponding fault
Emergency plug
disconnection
Return to standby mode after emergency disconnection
Safety & certification
Insulating strength
Input L&N-PE
Output L&N-PE
Input L&N-CP
AC:2U+1200V
60S, <20mA
During testing, the test sample must not exhibit insulation breakdown or arcing phenomena at any test point
Insulation resistance
Input L&N-PE
Output L&N-PE
Input L&N-CP
DC: 500V,
60S, >5MΩ
Test after short-circuiting the input L and N, as well as the output L and N respectively
Certification
CE
TUV
Complete system testing
Note: The voltage and current accuracy is ±5%
Previous Page
No
Next page
Related products